Results & Achievements​


CISPR 14 – Conducted Emissions | Consultation & Problem Solving
Spectra EMC Lab provides EMC debugging and troubleshooting services across Australia.
Problem
A unit from Melbourne failed the CISPR 14 conducted emissions test.
Our Approach
  • Detailed design review
  • Root-cause EMC analysis
  • PCB layout improvements
  • Prototype Design and Testing
Result
The design changes were implemented and validated.
The unit successfully passed the test.
Outcome
This case demonstrates how practical EMC engineering and targeted design improvements can turn failures into compliance.